Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | GFUVE |
Model Number : | GF302C |
Certification : | CNAS, CE, UL, KEMA |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability : | 200sets |
Delivery Time : | 1-2weeks |
GF302C ISO17025 Portable Electrical Panel Meter Test Equipment 0.05% Precisionn
With Programmable AC DC voltage and current source
Calibrators are used to validate and adjust the accuracy of field
instrumentation, which can deteriorate over time due to harsh
environmental or process conditions, leading to plant shutdowns and
thus opportunity costs, or personnel injury. Calibrators ensure
that instruments are performing reliably and accurately by sourcing
and measuring precision signals. GFUVE offers an extensive
portfolio of handheld calibration equipment, including process
multimeters, pressure calibrators, and multi-function units.
GFUVE's calibrators are trusted for their:
This device is according to nation verification regulation
JJG124-2005 "ammeter, voltmeter, power meter and resistance meter
calibration regulations and the relevant countries standard
requirements and design three-phase 0.05 magnitude meter source
integration calibration device”. The core technology of this device
is with digital signal processor (DSP) and 16 high-speed digital
converter, which is composed of high precision work frequency
communication terminal; The signal source use the DSP and 16
high-speed digital-to-analog converters, which can control the sine
wave, distortion wave signal source; Equipment has high precision,
stable and reliable, and easy to operate flexible, and other
characteristics; Electric power system is used for electrical
measurement is the ideal calibration equipment.
Power Meter Calibration. Calibration is a one-time procedure that
happens at the factory. When your power meter is manufactured, the
calibration process essentially sets the relationship between the
force measurement input and output. The factory calibrates your
power meter by setting what is called the ‘slope’.
Panel Meter Calibrators bring portable calibration functions to the
field including voltage, current, frequency, power factor, phase,
VARS and synchroscope. Model GF302C is a complete, full functioning
package, while Model GF302C is an economic alternative if some
features, such as a hand-help control unit, are not required.
ISO 17025 accredited for Panel Meter Calibration
Adaptability
Calibrate anything from data loggers, temperature controllers,
thermometers, multimeters, and pressure transmitters
Source and measure voltage, current, resistance, temperature,
pressure, pulse and frequency
Ergonomic interfaces engineered to work with Yokogawa as well as
third party products
A host of functions for verifying equipment response including
output ramping, output stepping, and loop power (simultaneously
stimulate a device and measure its response)
Minimal Training
Quickly and efficiently get your plant personnel and contractors up
to speed so they can focus more time on their tasks
Intuitive controls allow users to quickly store setup files, save
data to internal memory, and alternate between sourcing and
measuring
It is suitable for power plant and substation work area of grid companies, test division and the instrument, and national levels measuring and testing institutions, such as railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc.
Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60 Hz or AC 110 V±10%, 50/60 Hz |
Communication Port | USB port |
AC voltage output | |
Range(U1,U2,U3) | 50 V, 100 V, 200 V, 400 V, 800 V |
Adjusting range | (0-120) % RG |
Adjust fineness | 0.005% RG |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Load capacity | 25 VA |
Output distortion degree | ≤0.3% (linear load) |
AC current output | |
Range(I1,I2,I3) | 0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjusting range | (0-120) % RG |
Adjust fineness | 0.005% RG |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Load capacity | 25 VA |
Output distortion degree | ≤0.3% (linear load) |
DC voltage output | |
Range | 75 V, 150 V, 300 V, 500 V, 1000 V |
Adjusting range | (0-120) % RG |
Adjust fineness | 0.005% RG |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Load capacity | 25 VA |
DC current output | |
Range | 0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjusting range | (0-120)% RG |
Adjust fineness | 0.005% RG |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Load capacity | 25 VA |
AC power output | |
Accuracy | 0.05% RG |
Stability | 0.01%/1min |
Frequency | |
Frequency range | 45-65 Hz |
Resolution | 0.001 Hz |
Accuracy | 0.002 Hz |
Power factor output | |
Adjusting range | -1 to 0 to +1 |
Adjust fineness | 0.0001 |
Accuracy | 0.0005 |
Phase angle | |
Scope | 0°-359.99° |
Resolution | 0.01° |
Accuracy | 0.02° |
Voltage/Current harmonic output | |
Times | 2nd-31th |
Content | 0-40% |
Phase | 0°-359.999° |
Configuration error | (10% RD + 0.1%), RD refers to the configuration value of harmonic contents |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 460x430x185 |
Weight (kg) | 18 |
Environmental conditions | |
Working temperature | 0°C to 40°C |
Storage conditions | -30°C to 60°C |
Relative humidity | ≤85% |
PHOTOS
![]() |