Sign In | Join Free | My himfr.com
Home > Power Quality Analyzer >

IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy

    Buy cheap IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy from wholesalers
     
    Buy cheap IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy from wholesalers
    • Buy cheap IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy from wholesalers

    IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF438II
    Price :
    Payment Terms : T/T, Western Union
    Supply Ability : 10000
    Delivery Time : 1-2Week
    • Product Details
    • Company Profile

    IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy

    IEC6100-4-30 ClassA Power Quality Analyzer


    GF438II handheld three phase power quality analyzer offer the best ability in power quality analysis, GF438II handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.

    FEATURES

    • 3s statistical interval, continuously record 168h
    • Support multi-brand current transformer
    • Up to 32G data storage space
    • Record up to 461 power energy parameters simultaneously
    • Up to 10000 screenshots saved
    • Support periodic recording function
    • Up to 3.9M/s USB high-speed transfer
    • Recording wave
    • Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
    • Power inverter efficiency: simultaneously measure AC output power for power electronics systems.
    • Power wave data capture: GF438II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
    • Waveform capture: GF438II capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up
    • Automatic transient GF438II analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V.
    • Fully class-A compliant: GF438II analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard.
    • Mains signaling: GF438II analyzer measure interference from ripple control signals at specific frequencies.
    • Troubleshoot: analyze the trends using the cursors and zoom tools.
    • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
    • Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
    • Automatic trending: every measurement is always automatically recorded, without any set-up.
    • System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard
    • Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals.
    • View graphs and generate reports: with included analysis software.
    • Battery life: up to 5 hours operating time per charge on Li-ion battery pack.
      NameMeasurement type
      Voltagerms, ava, pk+, pk-, rms-1/2, CF
      FrequencyFreq
      Currentrms, ava, pk+, pk-, rms-1/2, CF
      Power & energyP, S, Q, PF, DPF, W
      ComputationTHD, DC, 1-63 Harm, 1-62 InHarm, 1-35 HiHarm, 1-62 SubHarm
      Voltage harmonicTHD, DC, 1-63 Harm, 0-62 InHarm, 1-35 HiHarm, 1-62 SubHarm , KF
      Current harmonicTHD, DC, 1-62 Harm
      Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
      Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
      UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
      Event logVoltage swell, voltage sags, DIP, surge current, voltage and current
      distortion out of limit, odd harmonics containing rate out of
      limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation, voltage harmonics out of
      limit, 2-25st harmonicsout of limit
      P, Q, S nameMeasurement type
      Measurement typesP: Calculate by every 10 cycles
      S: Calculated by the effective value of voltage and current
      Q: Calculated by the apparent power, active power
      DisplayTable charts, trend chart
      Measuring rangeAccording to the range of the voltage and current
      Resolution0.001W
      Accuracy±0.5%
      UrmsMeasurement type
      Mode'Calculated by the square root value of 10/12 cycle
      Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
      Basic frequency of the measuring circuit50Hz, 60Hz
      Input channels4 phase voltage, 4 phase current
      Display modeEffective current value of each channel
      Range120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
      Resolution0.001V
      Accuracy0.1% RG
      ArmsMeasurement type
      Mode'Calculated by the square root value of 10/12 cycle
      Display modeEffective current value of each channel
      RangeCurrent: according to the current clamps
      Option Current clamps:5A/50A/100A/500A/1000A
      Flexible Current probe: 1000A/3000A/6000A
      Resolution0.001A
      Accuracy0.1% + accuracy of the current clamps
      FrequencyMeasurement type
      Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
      Display modeMeasurement by 10 cycles
      Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
      Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
      Accuracy±0.001Hz
      Half-wave RMS current/voltageMeasurement type
      Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a
      waveform calculation
      Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,
      Current: According to the current clamps
      measurement accuracy±0.1%
      Power factorMeasurement type
      Measurement modeThe ratio of average power to apparent power
      Display modeReal-time data showed
      Measurement range/resolution-1.000-1.000/0.001
      Accuracy±0.1%
      Vfund, Afund, Harmonic powerMeasurement type
      Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
      Window points5120 points
      Display modeForm figure, trend charts, histograms
      Number of measurement1-50 Times
      Measurement accuracyVfund >1%: Error<1%
      Vfund <1%: Error<0.05% Rated Voltage
      Afund >3%: Error<1%
      Afund <3%: Error<0.05% Current range
      InHarm Voltage, InHarm currentMeasurement type
      Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
      Window points5120 points
      Display modeForm figure, trend charts, histograms
      Numbers of measurement1-16 groups
      Measurement accuracyVfund >1%: Error<1%
      Vfund <1%: Error<0.05% Rated Voltage
      Afund >3%: Error<1%
      Afund <3%: Error<0.05% Current range
      HiHarm Voltage, HiHarm currentMeasurement type
      Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
      Window points5120 points every 10 cycles
      Display modeForm figure, trend charts, histograms
      Numbers of measurement1-35 groups/2100Hz-8900Hz
      Measurement accuracyVfund >1%: Error<1%
      Vfund <1%: Error<0.05% Rated Voltage
      Afund >3%: Error<1%
      Afund <3%: Error<0.05% Current range
      Voltage/current Unbal (pos, neg)Measurement type
      Measurement mode3P3W or 3P4W, using three phase of fundamental wave
      components to calculate
      Display modeForm figure, trend charts, histograms
      Measurement accuracyVoltage unbal: ±0.2%
      Current unbal: ±0.5%
      Voltage fluctuationMeasurement type
      Measurement modeCalculate by the quadratic mean of half wave
      Display modeForm figure, trend charts
      Measurement accuracy±1%
      IEC FlickeringMeasurement type
      MeasurementP short term (Pst) , P long term (Plt)
      Measurement modeAccording to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt
      (2 hours)
      Display modeForm figure, trend charts
      Measurement range0-20
      Measurement accuracy±5%
      Surge currentMeasurement type
      Measurement modeHalf-wave RMS of current is higher than set value and sustain
      time is 10ms-1min
      Display modeMaximum of the surge current and surge current wave
      Measurement accuracy0.1%
      Voltage swell, Voltage sags, DIPMeasurement type
      Measurement modeSwell: When half-wave RMS of voltage is higher than set value
      and sustain time is 10ms-1min, judged as swell.
      Sags: When half-wave RMS of voltage is lower than set value and
      sustain time is 10ms-1min, judged as sags.
      DIP: half-wave RMS of voltage is higher than set value and sustain
      time is 10ms-1min, judged as DIP
      Display modeSwell, sags, DIP wave sustain time, extent and so on.
      Measurement accuracy0.1%
      Machinery
      Size263mm x 168mm x 65mm
      Key21PCS
      Binarybinary input:1 ; binary output:1
      Comunication PortUSB, 10/100M port
      Weight2KG
      Power supply
      Voltage input110V-240V
      Adapter outpu15V, 3A
      BatteryRechargeable nickel metal hydride, 5500mAh
      Battery working time≥ 6h
      Battery recharging time5h (Environment temperature 25°C)
      Power saving facilityLCD backlight brightness is adjustable, standby time is adjustable
      Display
      Size112.8 x 84.6mm
      Color260000 color
      Resolutions640 x 480
      BrightnessMax 350 cd/m2 (Typ), brightness is adjustable
      Contrast500:1 (Typ)
      Visual angle70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
      Environment
      Working environment0°C to +45°C, humidity below 90rh%
      Storing environment'-20°C to +50°C, humidity below 95rh% (non-condensing)
      Store
      TypeTF card (inbuilt)
      Size32G
      Standards
      Measurement methodIEC 61000-4-30
      Measurement performanceIEC 61000-4-30 A LVL
      FlickeringIEC 61000-4-15
      HarmonicIEC 61000-4-7
      Safety
      StandardGB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and
      laboratory electrical equipment safety requirements", first part:
      general requirements. Security level: CAT III 1000 V/ CAT IV 600 V./td>
      MAX voltage of phase angle inputCAT III 1000V/CAT IV 600V

    Quality IEC6100-4-30 Class A Power Quality Analyzer 0.001V Resolution High Accuracy for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message: