Sign In | Join Free | My himfr.com
Home > CT PT Analyzer >

GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification

    Buy cheap GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification from wholesalers
     
    Buy cheap GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification from wholesalers
    • Buy cheap GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification from wholesalers
    • Buy cheap GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification from wholesalers
    • Buy cheap GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification from wholesalers

    GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF1061
    Certification : CE
    Price :
    Payment Terms : T/T, Western Union
    Supply Ability : 10SET/MONTH
    • Product Details
    • Company Profile

    GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification

    PORTABLE PRECISION CURRENT TRANSFORMER TESTING CT PT ANALYZER


    GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.

    MAIN FUNCTIONS

    I. Current Transformer (CT)II. Voltage Transformer (PT)
    1. Magnetization curve1. Excitation characteristic test
    2. Transformation ratio test2. Transformation ratio test
    3. Polarity3. Polarity
    4. 5% and 10% error curve4. Ratio error, phase error
    5. Accuracy limiting factor (ALF)5. Degauss
    6. Degauss6. Calculation of knee point value
    7. Ratio error, phase error7. Actual secondary load test (burden test)
    8. Automatic calculation of excitation knee
    point value
    8. Resistance test
    9. Actual secondary load test (burden test)
    10. Resistance test 
    11. Secondary time constant (Ts)
    12. Remanence coefficient (Kr)
    13. Transient dimensioning factor (Ktd)
    14. Peak instantaneous error (Er)
    15. Magnetizing inductance (LU)
    16. Instruments security factor(FS)
    17. Composite error

    PARAMETERS

    Electrical parameters
    Accuracy0.05%
    Power supplyAC 220V±10% or AC 120V±10%, 50/60Hz or Battery
    Output voltage0-100Vrms
    Output current0-5Arms (20A peak-value)
    Output power0-400 VA (1500 VApeak)
    Automatic frequency variation range0.1-60Hz
    Equivalent excitation voltage≤5000V
    Accuracy≤0.5%
    Secondary winding DC resistance measurementRange0.1-1000Ω
    Accuracy≤0.05%
    Secondary actual load measurementRange5VA-1000VA
    Accuracy≤0.5%±0.1VA
    CT/PT phase error measurementAccuracy±1min (typical) / 3 min (guaranteed)
    Resolution0.1min
    CT ratio error measurementRange1-50000
    Accuracy≤0.05%
    PT ratio error measurementRange1-10000
    Accuracy≤0.05%
    Standards 
    Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
    IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
    Safety standardsGB 4793.1-2007
    EMCEMC standard 89/336/EEC
    FCC Subpart B of Part 15 Class A
    IEC 1000-4-2 /3 /4 /6
    Mechanical parameters 
    Overall dimension (L x W x H) (mm)280 x 250 x 160
    Weight (kg)≤4
    Environmental conditions 
    Relative humidityRelative humidity 5%-95% not condensing
    Operating temperature-10°C to +50°C
    Storage temperature-20°C to +70°C
    Altitude≤1000m