Sign In | Join Free | My himfr.com
Home > Secondary Current Injection Test >

TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control

    Buy cheap TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control from wholesalers
     
    Buy cheap TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control from wholesalers
    • Buy cheap TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control from wholesalers
    • Buy cheap TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control from wholesalers
    • Buy cheap TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control from wholesalers
    • Buy cheap TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control from wholesalers
    • Buy cheap TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control from wholesalers

    TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : TEST-630
    Certification : CE,CNAS
    Price :
    Payment Terms : T/T, Western Union
    Supply Ability : 100set/month
    • Product Details
    • Company Profile

    TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control

    TEST-630 SIX PHASE UNIVERSAL PROTECTION DEVICE RELAY TEST KIT

    Test-630 is a six phase current output and six phase voltage output protection relay tester with 5.Eight pairs of binary input and four pairs of binary output
    • Integration in the host crystal 8.4 inches true color, light weight and easy to carry.
    • Built-in high-speed and high-performance industrial computer embedded operating system, running stable and reliable, also can test by connecting PC.
    • Panel embedded user-friendly buttons, and the panel can also be an external keyboard and mouse.
    • High-precision DAC to 12 Road, simultaneously output to ensure the high precision and good linearity of the waveform.
    • 5Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can connect the electromagnetic compatibility to test.
    • Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and the test parameters of the surveillance.
    • The latest thermal structure design to ensure the best ventilation. Automatically determine over current, over voltage, overload and short circuit, if the temperature is too high, the anomalies and misuse warning of the data will show up promptly.
    • Using voltage, current amplifier AC / DC sharing, output stage uses a unique ultra-linear amplifier technology, high precision and reliability. six-phase AC output voltage and six-phase AC current.
    • 12 analog ports and other optional auxiliary DC source output (220V/110V).
    • Interface: RJ45 (Ethernet interface), USB interface (software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use).

    OVERVIEW

    • Six-channel current output
    • Six-channel voltage output
    • Eight pairs of binary input
    • Four pairs of binary output

    FUNCTIONS

    • Host real-time operating system, fast response, when faced with an emergency situation, can better protect the instruments and equipment under test. Safe and reliable, not easy to be violated by a computer virus.
    • The newly designed software interface style, the host machine operation is fully consistent with the background and easy to use.
    • Extensive testing capabilities: the state sequence will be determined to meet the needs of various types of user for testing microprocessor-based protection relay in the trial, IT features analog oscillation, the entire group of tests, differential protection, harmonic superposition, low cycle load shedding, same equipment, measuring instruments, GPS synchronized debugging, fault playback, and custom test (special tests), etc. It can easily complete the protective device test of ABB, Siemens, AREVA and other foreign manufacturers.
    • The test report can be easily derived from the USB port to print.

    TEST ITEM

    • U/I Test
    • DC Test
    • Impedance Characteristics
    • Power Direction Test
    • I-T Test
    • Differential Relay
    • Harmonic Test
    • Differential Protection
    • Distance Protection
    • Zero Sequence Protection
    • Setting Group Test
    • State Sequence
    • Synchronization Test
    • Special Test
    • Oscillation Test
    • Metering Instrument
    • Hardware Checkout
    • Low Voltage Protection
    • Fault Recurrence

    PARAMETERS

    Electrical parameters 
    Allowable rangeAC220V±10% or AC110V±10%, 50/60Hz±10%
    Time measurement0.1ms-999999.999s
    AC current output 
    Phase current output (effective value)6×0-30A or 3 × 0-60A
    Maximum output power520VA/phase
    Maximum parallel current output (effective value)0-180A
    Long-term allowable working value of phase current (effective value)>10A
    Allowable working time of maximum current>11s
    Accuracy<±0.2%
    AC voltage output 
    Phase voltage output (effective value)6×0-130V
    Line voltage output (effective value)0-260V
    Maximum output power70VA/phase
    Accuracy<±0.2%
    DC voltage output 
    Output range0-300V or 6×0-±130V
    Maximum output power130VA
    Accuracy<±0.2%
    DC current output 
    Output range-10-10A or 6×0-±10A
    Maximum output power150VA
    Accuracy<±0.2%
    Binary input 
    Idle contact1-20mA, 24V (DC)
    Electric potential contact0-250V (DC)
    Binary output 
    Idle contact250V/0.5A (DC)
    Rated output 
    Frequency error<±0.01HzHz
    Phase error<±0. 2°
    Waveform distortion<±0.3% (fundamental wave)
    Time error<40µs
    Output frequency0-1050Hz
    Superposed harmonic wave0-21times
    Time measurement 
    Test range0.1ms-999999.999s
    Mechanical parameters 
    Dimensions (L×W×H) (mm)360×195×365
    Weight (kg)16.6
    Environmental conditions 
    Use range0°C to 45°C
    Storage range-25°C to 70°C
    Quality TEST-630 Secondary Injection Test Set Relay Test Equipment Six Phase Program Control for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)