Sign In | Join Free | My himfr.com
Home > CT PT Analyzer >

Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display

    Buy cheap Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display from wholesalers
     
    Buy cheap Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display from wholesalers
    • Buy cheap Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display from wholesalers

    Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF106T
    Certification : CE, UL, ISO9001, KEMA
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000sets/Month
    Delivery Time : 1-2weeks
    • Product Details
    • Company Profile

    Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display

    GF106T Current Transformer Calibration Device With Turn Ratio Transformer Test CT PT Analyzer


    GF106T Portable Instrument Current Transformer calibration device is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.


    MAIN FUNCTIONS

    I. Current Transformer (CT)II. Voltage Transformer (PT)
    1. Magnetization curve1. Excitation characteristic test
    2. Transformation ratio test2. Transformation ratio test
    3. Polarity3. Polarity
    4. 5% and 10% error curve4. Withstand test of power frequency alternating current
    5. Current Injecting5. Degauss
    6. Degauss6. Calculation of knee point value
    7. Withstand test of power frequency alternating current7. Actual secondary load test 
    8. Automatic calculation of excitation knee
    point value
    8. Resistance test
    9. Actual secondary load test 
    10. Resistance test 

    PARAMETERS

    Electrical parameters
    Accuracy0.2%, 0.5%
    Power supplyAC 220V±10% or AC 110V±10%, 50/60Hz
    Excitation voltage output0-2500Vrms,
    Excitation current output0-5Arms (20A peak-value)
    Large current output0-1000A
    Electrical parameters - continued
    Accuracy≤0.5% (0.2%RD+0.3%RG)
    Secondary winding DC resistance measurementRange0.1-300Ω
    Accuracy≤0.5% (0.2%RD+0.3%RG)
    Secondary actual load measurementRange5VA-1000VA
    Accuracy≤0.5% (0.2%RD+0.3%RG)±0.1VA
    CT/PT phase error measurementAccuracy±4min
    Resolution0.01min
    CT ratio error measurementRange≤25000A/5A(5000A/1A)
    Accuracy≤0.5%
    PT ratio error measurementRange1-500KV
    Accuracy≤0.5%
    Standards 
    Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
    IEC60044-1, IEC60044-6, IEC61869-2-2012
    Safety standardsGB 4793.1-2007
    EMCEMC standard 89/336/EEC
    FCC Subpart B of Part 15 Class A
    IEC 1000-4-2 /3 /4 /6
    Mechanical parameters 
    Overall dimension (L x W x H) (mm)400 x 250 x 250
    Weight (kg)≤22
    Environmental conditions 
    Relative humidity90RH%
    Operating temperature-10°C to +40°C
    Altitude≤1000m

    Photo


    Quality Current Transformer Calibration CT PT Analyzer 4 Min Phase With 6.4 Inch LCD Display for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)