Sign In | Join Free | My himfr.com
Home > CT PT Analyzer >

Precision Current Transformer Analyzer / Power Transformer Testing Equipment

    Buy cheap Precision Current Transformer Analyzer / Power Transformer Testing Equipment from wholesalers
     
    Buy cheap Precision Current Transformer Analyzer / Power Transformer Testing Equipment from wholesalers
    • Buy cheap Precision Current Transformer Analyzer / Power Transformer Testing Equipment from wholesalers
    • Buy cheap Precision Current Transformer Analyzer / Power Transformer Testing Equipment from wholesalers
    • Buy cheap Precision Current Transformer Analyzer / Power Transformer Testing Equipment from wholesalers

    Precision Current Transformer Analyzer / Power Transformer Testing Equipment

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF106T
    Certification : GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2-2012
    Price :
    Payment Terms : T/T, Western Union
    Supply Ability : 200
    Delivery Time : 1-2week
    • Product Details
    • Company Profile

    Precision Current Transformer Analyzer / Power Transformer Testing Equipment

    CT PT Analyzer GF106T


    Ct/Pt Analyzer/Instrument Transformer Testing/Ta/Tv Analyzer /Pt Test System


    I. Current Transformer (CT)II. Voltage Transformer (PT)
    1. Magnetization curve1. Excitation characteristic test
    2. Transformation ratio test2. Transformation ratio test
    3. Polarity3. Polarity
    4. 5% and 10% error curve4. Withstand test of power frequency alternating current
    5. Current Injecting5. Degauss
    6. Degauss6. Calculation of knee point value
    7. Withstand test of power frequency alternating current7. Actual secondary load test 
    8. Automatic calculation of excitation knee
    point value
    8. Resistance test
    9. Actual secondary load test 
    10. Resistance test 

    PARAMETERS

    Electrical parameters
    Accuracy0.2%, 0.5%
    Power supplyAC 220V±10% or AC 110V±10%, 50/60Hz
    Excitation voltage output0-2500Vrms,
    Excitation current output0-5Arms (20A peak-value)
    Large current output0-1000A
    Electrical parameters - continued
    Accuracy≤0.5% (0.2%RD+0.3%RG)
    Secondary winding DC resistance measurementRange0.1-300Ω
    Accuracy≤0.5% (0.2%RD+0.3%RG)
    Secondary actual load measurementRange5VA-1000VA
    Accuracy≤0.5% (0.2%RD+0.3%RG)±0.1VA
    CT/PT phase error measurementAccuracy±4min
    Resolution0.01min
    CT ratio error measurementRange≤25000A/5A(5000A/1A)
    Accuracy≤0.5%
    PT ratio error measurementRange1-500KV
    Accuracy≤0.5%
    Standards 
    Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
    IEC60044-1, IEC60044-6, IEC61869-2-2012
    Safety standardsGB 4793.1-2007
    EMCEMC standard 89/336/EEC
    FCC Subpart B of Part 15 Class A
    IEC 1000-4-2 /3 /4 /6
    Mechanical parameters 
    Overall dimension (L x W x H) (mm)400 x 250 x 250
    Weight (kg)≤22
    Environmental conditions 
    Relative humidity90RH%
    Operating temperature-10°C to +40°C
    Altitude≤1000m
    Quality Precision Current Transformer Analyzer / Power Transformer Testing Equipment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)