Sign In | Join Free | My himfr.com
Home > Primary Injection Test Equipment >

6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy

    Buy cheap 6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy from wholesalers
     
    Buy cheap 6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy from wholesalers
    • Buy cheap 6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy from wholesalers
    • Buy cheap 6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy from wholesalers
    • Buy cheap 6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy from wholesalers
    • Buy cheap 6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy from wholesalers

    6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : TEST-902
    Certification : ISO9001, CE, KEMA
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 200SETS
    Delivery Time : 2WEEKS
    • Product Details
    • Company Profile

    6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy

    TEST-902 Low Voltage Circuit Breakers & Relay of 2000A Primary and Secondary Current Injection Tester


    TEST-902 Primary Current Injection Tester could simultaneously display primary current, secondary current and turn ratio. It is mainly suited for CT turn ratio and contact resistance tests of power system and other occasions needed high current test.
    2000A Primary Current Injection Tester of TEST-902 is applied in power system for circuit breaker test, protection system test and current transformer test. The tester generates 2000A high current from power supply to simulate the rated current or fault current in the primary circuit of power equipment.

    TEST-902 is mainly applied to test CT turn ratio in the power system and the contact resistance etc, which need large current.


    This powerful test system is designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the turns ratio of current transformers and for other applications that require high variable currents.


    The system consists of a control unit and a current unit. The two parts are portable, and TEST-902 can be quickly assembled and connected.


    The control unit has many advanced features – a powerful measurement section for example, that can display turns ratio as well as time, voltage and current. A second measurement channel can be used to test an additional current or voltage. Current transformer turns ratio, impedance, power, power factor (cos φ) and phase angle are calculated and shown in the display. Current and voltage can be presented as percentages of nominal value. The fast-acting hold function freezes short-duration readings on the digital display when the voltage or contact signal arrives at the stop input, the object under test interrupts the current or injection is stopped.


    FEATURES


    • Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
    • Modular design to permit optimal user configuration of output current vs. unit size
    • Compact transport cart facilitates portability into switchgear rooms with limited space
    • Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result

    PARAMETERS

    Electrical parameters 
    Accuracy±0.5%
    Power Supply (AC)220V±10%·50A, 50Hz/60Hz or
    110V±10%·100A, 50Hz/60Hz
    Current Output (AC)2000A·6V or 1000A·12V
    Capacity12KVA
    The current output waveform distortion≤5%
    Primary current 
    Range0-2200A
    Resolution0.1A
    Accuracy<0.5%
    Secondary measurement 
    Range0-6A
    Resolution0.001A
    Accuracy<0.5%
    Current duration 
    2000A range2000A 2-3minutes
    1000A 3-6minutes
    1000A range1000A 2-3minutes
    With timer
    Range0.0001~999.99S
    Resolution0.001S
    Accuracy<0.5%±5 words
    Mechanical parameters 
    Dimensions (W×D×H) (mm)360×300×295and320×300×300
    Weight (kg)Control Host 35kg,
    External voltage regulator weight 15kg
    Environmental conditions 
    Temperature-10°C to 40°C
    Relative humidity≤80%

    SELECTION GUIDE

    ModelACCU
    RACY
    Primary
    current
    AMMETER
    (0-6A)
    TIMERPOWERINJECTION CURRENT TIMEDIMENSION(W×D×H)(mm)WEIGHTREMARK
    TEST-9010.5%0-1100AYESYES5KVA1000A: 2-3min;
    500A:3-6min
    430×260×26025KGIntegrated structure
    TEST-9020.5%0-2200AYESOPTIONAL12KVA2000A:2-3min;
    1000A:3-6min
    360×300×295 and 320×300×30035KG+15KGFission structure
    TEST-9030.5%0-3300AYESOPTIONAL15KVA3000A:2-3min;
    1500A:3-6min
    380×350×360 and 340×290×42048KG+42KGFission structure
    TEST-9050.5%0-5500AYESOPTIONAL25KVA5000A:2-3min;
    2500A:3-6min
    430×430×445 and 550×450×60068KG+55KGFission structure

    Quality 6m Cable Length Primary Current Injection Test Equipment 0.5% Accuracy for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)