Sign In | Join Free | My himfr.com
Home > Power Quality Analyzer >

Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing

    Buy cheap Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing from wholesalers
     
    Buy cheap Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing from wholesalers
    • Buy cheap Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing from wholesalers
    • Buy cheap Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing from wholesalers
    • Buy cheap Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing from wholesalers
    • Buy cheap Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing from wholesalers

    Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF438II
    Certification : IEC61000-4-30 CLASS A
    Price :
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 300sets/month
    Delivery Time : 3-7days
    • Product Details
    • Company Profile

    Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing


    GF438II GFUVE IEC 61000-4-30 CLASS A Three Phase Power Quality Analyzer With flicker & 63rd harmonics


    GFUVE GF438II class A power quality analyzers can help you discover the state of health of your power systems. Designed to meet the needs to the intended measurement task, power quality analyzers help you beprepared for any power quality issues.The Power Quality analyzers that can monetize the cost of energy waste due to poor power quality. More powerful sampling options, greater accuracy and larger memory makes the GF438II better for longer term, higher resolution or more demanding power quality studies.

    Class A power quality (PQ) analyzers are used for this per IEC 61000-4-30. The regular testing and calibration of these devices has presented manufacturers, commissioners and equipment maintenance personnel with new challenges. For instance, the standard IEC 62586 requires different PQ parameters to be swapped during extensive type tests.

    GF438II handheld three phase power quality analyzer offer the best ability in power quality analysis, GF438II handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.

    Power Quality Analysers. Power Quality Analysers are powerful and versatile instruments available to the modern electrician and electrical engineer. Our complete range of Class A and Class S Power Quality Analysers can be used for diagnosing Power Quality problems, Energy Load Profiling and for producing Harmonic Surveys of an electrical installation.


    The GFUVE GF438II power quality analyzers are designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime.

    • Measure multiple parameters simultaneously to quickly understand overall power quality health
    • View data as simple digital values or more detailed trend graphs that give you fast insight into changes over time, waveforms, and phasor diagrams
    • Organize data in tabular format so you can quickly correlate parameters like magnitude, duration, and time to the issues you are experiencing in your facility

    APPLICATION

    Electrical Power Systems
    Power Plants
    Photovoltaic
    Distribution


    Industrial Systems
    LV Installations Safety / Quality
    UPS Systems testing
    Switchboards / Controlgears
    Machines / Power Loads
    Electrical Equipment / Appliances
    Maintenance / Troubleshooting
    3-phase system testing
    High level industrial testing
    Mid level industrial testing


    Buildings Facility Management
    Public areas Safety / Quality
    Voltage Quality / Power Loads


    Special Installations / Locations
    Construction Sites
    Railway Systems
    Ships / Boats / Marina Places
    Fire Brigade Vehicles
    Military / Police Vehicles
    Mobile LV Generator Units
    Medical Sites / Surgery Rooms
    Laboratory use
    Service / Repair / Rental Offices
    Electric motors testing

    FEATURES

    • 3s statistical interval, continuously record 168h
    • Support multi-brand current transformer
    • Up to 32G data storage space
    • Record up to 461 power energy parameters simultaneously
    • Up to 10000 screenshots saved
    • Support periodic recording function
    • Up to 3.9M/s USB high-speed transfer
    • Recording wave

    FUNCTIONS

    • Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
    • Power inverter efficiency: simultaneously measure AC output power for power electronics systems.
    • Power wave data capture: GF438II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
    • Waveform capture: GF438II capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up
    • Automatic transient GF438II analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V.
    • Fully class-A compliant: GF438II analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard.
    • Mains signaling: GF438II analyzer measure interference from ripple control signals at specific frequencies.
    • Troubleshoot: analyze the trends using the cursors and zoom tools.
    • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
    • Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
    • Automatic trending: every measurement is always automatically recorded, without any set-up.
    • System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard
    • Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals.
    • View graphs and generate reports: with included analysis software.
    • Battery life: up to 5 hours operating time per charge on Li-ion battery pack.

    PARAMETERS

    NameMeasurement type
    Voltagerms, ava, pk+, pk-, rms-1/2, CF
    FrequencyFreq
    Currentrms, ava, pk+, pk-, rms-1/2, CF
    Power & energyP, S, Q, PF, DPF, W
    ComputationTHD, DC, 1-63 Harm, 1-62 InHarm, 1-35 HiHarm, 1-62 SubHarm
    Voltage harmonicTHD, DC, 1-63 Harm, 0-62 InHarm, 1-35 HiHarm, 1-62 SubHarm , KF
    Current harmonicTHD, DC, 1-62 Harm
    Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
    Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
    UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
    Event logVoltage swell, voltage sags, DIP, surge current, voltage and current
    distortion out of limit, odd harmonics containing rate out of
    limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation, voltage harmonics out of
    limit, 2-25st harmonicsout of limit
    P, Q, S nameMeasurement type
    Measurement typesP: Calculate by every 10 cycles
    S: Calculated by the effective value of voltage and current
    Q: Calculated by the apparent power, active power
    DisplayTable charts, trend chart
    Measuring rangeAccording to the range of the voltage and current
    Resolution0.001W
    Accuracy±0.5%
    UrmsMeasurement type
    Mode'Calculated by the square root value of 10/12 cycle
    Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
    Basic frequency of the measuring circuit50Hz, 60Hz
    Input channels4 phase voltage, 4 phase current
    Display modeEffective current value of each channel
    Range120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
    Resolution0.001V
    Accuracy0.1% RG
    ArmsMeasurement type
    Mode'Calculated by the square root value of 10/12 cycle
    Display modeEffective current value of each channel
    RangeCurrent: according to the current clamps
    Option Current clamps:5A/50A/100A/500A/1000A
    Flexible Current probe: 1000A/3000A/6000A
    Resolution0.001A
    Accuracy0.1% + accuracy of the current clamps
    FrequencyMeasurement type
    Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
    Display modeMeasurement by 10 cycles
    Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
    Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
    Accuracy±0.001Hz
    Half-wave RMS current/voltageMeasurement type
    Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a
    waveform calculation
    Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,
    Current: According to the current clamps
    measurement accuracy±0.1%
    Power factorMeasurement type
    Measurement modeThe ratio of average power to apparent power
    Display modeReal-time data showed
    Measurement range/resolution-1.000-1.000/0.001
    Accuracy±0.1%
    Vfund, Afund, Harmonic powerMeasurement type
    Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
    Window points5120 points
    Display modeForm figure, trend charts, histograms
    Number of measurement1-50 Times
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    InHarm Voltage, InHarm currentMeasurement type
    Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
    Window points5120 points
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-16 groups
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    HiHarm Voltage, HiHarm currentMeasurement type
    Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
    Window points5120 points every 10 cycles
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-35 groups/2100Hz-8900Hz
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range

    Photo


    Quality Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)