GF303D 200a Portable Three Phase AC phantom Load Electrical Power Calibrator for testing watthour meter
GF303D portable 3 phase ac phantom load Electrical Power Calibrator
is suitable for power department, measuring department, quality
control department, research units, and institutions of higher
learning, and electric energy meter, power distribution terminals,
power supply management, load control, power quality, reactive
power compensation device and the production of enterprise etc.
A phantom load is any electricity that an appliance or device
consumes even when it’s turned off. These phantom loads, also
commonly referred to as vampire loads, can be small for individual
appliances but will add up quickly over the course of the month or
year.
GFUVE Electronics is a leading manufacturer of electronic energy
phantom load power source in China. We supply stationary or
portable test equipment, power sources, reference standards, Electrical Power Calibrator, relay test set, ct pt analyzer etc.
The new GF303D portable three phase phantom load stable Electrical Power Calibrator, designed from new digital wave compound technology and according
to International Standard, is newly intelligent equipment for
energy meters.
Three Phase Programmable Phantom Load. The instrument is used for
the calibration of high accuracy signal source in power system. And
it is mainly applied in utilities, Measurement Bureaus, Quality
Control System, Science & Technology Unit and Manufacturers for
energy meter, terminals, load control, power quality analysis ...
The GFUVE Calibration GF3031 Three Phase Electrical Power
Calibrator is the most cost-effective way to get the superior
accuracy and performance of three independent phases in one
instrument. It is an ideal solution for calibration laboratories,
electronics manufacturers, electric utility meter shops, and other
organizations that manufacture and maintain energy meters, power
quality analyzers, and similar tools.
The GF3031 AC Electrical Power Calibrator is equipped with RS232
PORT as standard communication interface to control external
devices remotely. Power Factor Validation Power factor is an
important element when users judge the efficiency of a device.
FEATURES
- To set up and take the load regulation of voltage, current, phase
angle ,frequency and power factor etc; as a large current source,
voltage source and power source
- To set 2 ~ 51 times of the amplitude and phase harmonics, and it
can be added to the base wave in every harmonic output
- Voltage, current output a wide range, big power, high stability,
waveform distortion degree is small
- Strong with load ability, but it can take capacitive, sensibility,
resistance of composite type load or load and load regulation is
higher than 0.01%
- To apply the 32 bit MPU + DSP + CPLD, powerful flexible
- To use hardware PID, fast response, the change of load will not
cause output volatility
- Industrial frequency waves as high as 5000 points a week of the
wave kneading, signal output without filter, precise output
waveform, the harmonic output precision, harmonic distortion degree
is small
- Range switching automatically
- To use software calibration, simple operation, stable and reliable
- Display of vector diagram, adjustable to IEC387 OR DIN410
- Big touch screen, 7-inch TFT color LCD display, English interface,
operating simply
- To have perfect over-current, over-voltage, heat, a
shorts-and-opens, overload protection, failure detection
automatically
- With RS232 interface, and PC connection
- To take place machine software, it can be output through the PC
software program
PARAMETERS
Electrical parameters |
---|
Accuracy class | 0.02%, 0.05%, 0.1% |
Power supply | Single phase AC 85-265 V, frequency 50/60 Hz |
AC Voltage output |
---|
Range (U1, U2, U3 phase) | 57.7V/100V/220V/380V; range switch automatically(Max 500V) |
Adjust fineness | 0.01% RG |
Accuracy | 0.05% RG |
Stability | <0.01% RG/120s |
Distortion degree | <0.3% (not capacitive load) |
Output power | 25VA |
Full load regulation rate | 0.01% RG |
Full load regulation time | Less than 1mS |
Long-term stability | ± 60 PPM/year |
AC Current output |
---|
Range (I1, I2, I3 phase) | 0.2A, 1A, 5A, 20A, 100A, 200A; range switch automatically |
Adjustment range | (0-120)%RG |
Adjust fineness | 0.01% RG |
Accuracy | 0.05% RG |
Stability | <0.01% RG/120s |
Distortion degree | <0.3% (not capacitive load) |
Output power | 100VA |
Full load regulation rate | 0.01% RG |
Full load regulation time | Less than 1mS |
Long-term stability | ± 60 PPM/year |
Power output |
---|
Accuracy | 0.05% RG |
Stability | 0.01% RG/120s |
Phase angle |
---|
Adjusting range | 0°-359.99° |
Resolution | 0.001° |
Accuracy | 0.02° |
Power factor |
---|
Adjusting range | -1 ~ 0 ~ +1 |
Resolution | 0.0001 |
Accuracy | 0.0005 |
Frequency |
---|
Adjusting range | 40-70 Hz |
Resolution | 0.001 Hz |
Accuracy | 0.005 Hz |
Temperature drift | ± 0.5 PPM/°C |
Long-term stability | ± 4 PPM/year |
Harmonic accuracy |
---|
Harmonic phase | 0°-359.99° |
Harmonic phase accuracy | < 0.01° |
Harmonic set accuracy | 0.1% (relative to the base wave ratings) |
Mechanical parameters |
---|
Dimensions (W×D×H) (mm) | 500x600x175 |
Weight (kg) | 27 |
Environmental conditions |
---|
Working temperature | 0°C to 40°C |
Storage condition | -30°C to -60°C |
Relative humidity | ≤ 85% |
SELECTION GUIDE
NO. | Accuracy | Voltage range | Current Range | Weight |
---|
303D1201 | 0.10% | 0-500V | 0-120A | 25KG |
303D12005 | 0.05% | 0-500V | 0-120A | 25KG |
303D1201 | 0.10% | 0-380V | 0-12A | 18KG |
303D1205 | 0.05% | 0-380V | 0-12A | 18KG |
303D2401 | 0.10% | 0-500V | 0-24A | 20KG |
303D2405 | 0.05% | 0-500V | 0-24A | 20KG
|