    Brand Name : GFUVE
    Model Number : GF1061PT
    Certification : CE, ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 200SETS/MONTH
    Delivery Time : 2-3weeks
    • Product Details
    • Company Profile

    4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy

    IEC60044-2 & IEC61869-1, 3 GF1061PT Portable CT PT voltage transformer Analyzer with printer


    GF1061PT Portable GFUVE potential transformer Analyzer with PT testing function, current transformer testing


    GF1061 portable GFUVE CT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.


    The MODEL GF1061PT Voltage Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service.


    Sophisticated testing of inductive and capacitive voltage transformers GF1061PT is the first portable device which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration.


    FUNCTIONS


    Injects low test signals into secondary side of the CT

    Determines the CT‘s equivalent circuit parameters

    Identifies all relevant CT performance parameters

    Displays all relevant parameters of the CT and its accuracy at different currents and burdens

    Evaluates the CT according to the selected standard

    Determines unknown CT nameplate parameters

    Demagnetizes the CT after the test


    Ratio and phase accuracy
    Winding resistance
    Excitation characteristics (knee points)
    Composite error (ALF, ALFi, FS, FSi, Vb)
    Burden impedance
    Transient CT classes and parameters
    (TPS, TPX, TPY and TPZ type CTs)
    Transient dimensioning factor (Ktd)
    If missing/unknown: CT type, class, ratio, knee point, power factor, nominal burden, operating burden, primary and secondary winding resistance
    Remanence and residual magnetism
    Immediate good/bad evaluation


    Features


    1. Steady and transient state characteristic tests of various types of CT/PT


    2. The use of advanced power technology, the test knee point reaches up to 50kV


    3. No external other auxiliary equipment, stand-alone to complete all test items


    4. CT test, easy to test, all the tests are using the same wire connection except the load test


    5. It carries with thermal printer, so it can print test results on site Reference Standard IEC 60044, ANSI/ IEEE C57.13, IEC61869, GB 1207-2006, GB 1208-2006


    6. Parameters such as knee point current and voltage


    7. Parameters such as 10% error curve, 5% error curve


    8. With battery, working 7days.


    9. The device can store 10000 groups of test data which would not be lost if the device is power off.


    10. The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report


    11. Portability: weight <4kg, the best light ct analyzer


    MAIN FUNCTIONS


    I. Current Transformer (CT)II. Voltage Transformer (PT)
    1. Magnetization curve1. Excitation characteristic test
    2. Transformation ratio test2. Transformation ratio test
    3. Polarity3. Polarity
    4. 5% and 10% error curve4. Ratio error, phase error
    5. Accuracy limiting factor (ALF)5. Degauss
    6. Degauss6. Calculation of knee point value
    7. Ratio error, phase error7. Actual secondary load test (burden test)
    8. Automatic calculation of excitation knee
    point value
    8. Resistance test
    9. Actual secondary load test (burden test)
    10. Resistance test 
    11. Secondary time constant (Ts)
    12. Remanence coefficient (Kr)
    13. Transient dimensioning factor (Ktd)
    14. Peak instantaneous error (Er)
    15. Magnetizing inductance (LU)
    16. Instruments security factor(FS)
    17. Composite error

    PARAMETERS

    Electrical parameters
    Accuracy0.05%
    Power supplyAC 220V±10% or AC 120V±10%, 50/60Hz or Battery
    Output voltage0-100Vrms
    Output current0-5Arms (20A peak-value)
    Output power0-400 VA (1500 VApeak)
    Automatic frequency variation range0.1-60Hz
    Equivalent excitation voltage≤5000V
    Accuracy≤0.5%
    Secondary winding DC resistance measurementRange0.1-1000Ω
    Accuracy≤0.05%
    Secondary actual load measurementRange5VA-1000VA
    Accuracy≤0.5%±0.1VA
    CT/PT phase error measurementAccuracy±1min (typical) / 3 min (guaranteed)
    Resolution0.1min
    CT ratio error measurementRange1-50000
    Accuracy≤0.05%
    PT ratio error measurementRange1-10000
    Accuracy≤0.05%
    Standards 
    Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
    IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
    Safety standardsGB 4793.1-2007
    EMCEMC standard 89/336/EEC
    FCC Subpart B of Part 15 Class A
    IEC 1000-4-2 /3 /4 /6
    Mechanical parameters 
    Overall dimension (L x W x H) (mm)280 x 250 x 160
    Weight (kg)≤4
    Environmental conditions 
    Relative humidityRelative humidity 5%-95% not condensing
    Operating temperature-10°C to +50°C
    Storage temperature-20°C to +70°C
    Altitude≤1000m

    Photo

    Quality 4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)