Sign In | Join Free | My himfr.com
Home > Primary Injection Test Equipment >

18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer

    Buy cheap 18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer from wholesalers
     
    Buy cheap 18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer from wholesalers
    • Buy cheap 18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer from wholesalers
    • Buy cheap 18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer from wholesalers
    • Buy cheap 18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer from wholesalers
    • Buy cheap 18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer from wholesalers

    18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : TEST-200
    Certification : ISO9001, CE, KEMA
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 200SETS
    Delivery Time : 7DAYS
    • Product Details
    • Company Profile

    18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer

    TEST-200 200A PRIMARY CURRENT INJECTION TEST SET FOR CURRENT TRANSFORMER ratio test


    200A PRIMARY CURRENT INJECTION TEST SET FOR CURRENT TRANSFORMER


    TEST-200 200A primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-200 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.

    The primary current injection method is usually the preferred test method because it includes the current sensors, wiring, and the current conduction path in the circuit breaker with the test. However, this method has one disadvantage in that it will not always detect sensor wiring and polarity problems.

    If performing three-phase primary injection is not feasible, the sensors and wiring of the circuit breaker should be tested separately to verify that they are working correctly. The proper functioning of the trip unit can be tested using primary current injection, one phase at a time. Two adjacent phases may also be connected in series and tested as three pairs to check for current sensor polarity issues.
    Because primary current injection testing is a relatively expensive service, it's usually performed only during the commissioning (start-up) process to supplement a program of periodic secondary-current testing. Circuit breakers that are part of a critical process or engineered safety system are often maintenance tested using primary injection due to their high reliability requirements.
    Primary current injection test set for low voltage power circuit breakers​

    PARAMETERS

    Electrical parameters 
    Accuracy±0.5%
    Power Supply(AC)220V±10%·5A, 50Hz/60Hz or
    110V±10%·10A, 50Hz/60Hz
    Current Output (AC)200A·5V or 100A·10V
    Capacity1KVA
    The current output waveform distortion≤5%
    Dual protectionoverload electronic protection and software protection
    Primary current 
    Range0-240A
    Resolution0.1A
    Accuracy<0.5%
    Secondary measurement 
    Range0-6A
    Resolution0.001A
    Accuracy<0.5%
    Current duration 
    200A range200A 2-3minutes
    100A 3-6minutes
    100A range100A 2-3minutes
    With timer
    Range0.0001~999.99S
    Resolution0.001S
    Accuracy<0.5%±5 words
    Mechanical parameters 
    Dimensions (W×D×H) (mm)430×260×260
    Weight(kg)20
    Environmental conditions 
    Temperature-10°C to 40°C
    Relative humidity≤80%

    SELECTION GUIDE

    ModelACCU
    RACY
    Primary
    current
    AMMETER
    (0-6A)
    TIMERPOWERINJECTION CURRENT TIMEDIMENSION(W×D×H)(mm)WEIGHTREMARK

    TEST-901

    0.5%0-1100AYESYES5KVA1000A: 2-3min;
    500A:3-6min
    430×260×26025KGIntegrated structure
    TEST-9020.5%0-2200AYESOPTIONAL12KVA2000A:2-3min;
    1000A:3-6min
    360×300×295 and 320×300×30035KG+15KGFission structure
    TEST-9030.5%0-3300AYESOPTIONAL15KVA3000A:2-3min;
    1500A:3-6min
    380×350×360 and 340×290×42048KG+42KGFission structure
    TEST-9050.5%0-5500AYESOPTIONAL25KVA5000A:2-3min;
    2500A:3-6min
    430×430×445 and 550×450×60068KG+55KGFission structure
    TEST-2000.5%0-240AYESYES1KVA200A: 2-3min;
    100A:3-6min
    430×260×26020KGIntegrated structure

    Quality 18KG Primary Current Injection Test Set 0-200A With CT Ratio Test And Timer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)