Sign In | Join Free | My himfr.com
Home > Primary Injection Test Equipment >

5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing

    Buy cheap 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing from wholesalers
     
    Buy cheap 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing from wholesalers
    • Buy cheap 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing from wholesalers
    • Buy cheap 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing from wholesalers
    • Buy cheap 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing from wholesalers
    • Buy cheap 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing from wholesalers

    5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : TEST-905-5000A
    Certification : ISO9001, CE, KEMA
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 200SETS
    Delivery Time : 30DAYS
    • Product Details
    • Company Profile

    5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing


    5000a Three Phase Primary Current Injection Test Set For Temperature rise testing


    TEST-905 5000a Three Phase Primary Current Injection Test Set For Temperature rise testing


    Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.

    Primary injection testing is suitable for testing over-current trip relays attached to a circuit breaker. By injecting the current into the system we can measure if the breaker will trip or fail, and how long the current is live before the circuit is broken.

    Circuit breakers can go long periods of time without activation, and failure at the moment of activation can cause catastrophic damage to the electrical system. Circuit breaker testing with primary current injection on a breaker that has not triggered in some time is the best way to recreate the real operating conditions of a current spike.


    TEST-905 5000A primary current injection test equipment adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-905 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current. and CT , circuit breaker, Switch temperature rise testing.

    This powerful test system is designed for primary injection testing of protective relay equipment and circuit breakers. It is also used to test the turns ratio of current transformers and for other applications that require high variable currents.


    The system consists of a control unit and a current unit. The two parts are portable, and INGVAR can be quickly assembled and connected.


    The control unit has many advanced features – a powerful measurement section for example, that can display turns ratio as well as time, voltage and current. A second measurement channel can be used to test an additional current or voltage. Current transformer turns ratio, impedance, power, power factor (cos φ) and phase angle are calculated and shown in the display. Current and voltage can be presented as percentages of nominal value. The fast-acting hold function freezes short-duration readings on the digital display when the voltage or contact signal arrives at the stop input, the object under test interrupts the current or injection is stopped.


    The TEST-905 is a programmable AC high-current source designed specifically for utility-substation applications. This device is well suited for primary injection testing of protective relays. This versatile device can also be used for testing thermal, magnetic, and solid-state motor-protection relays and molded-case circuit-breakers, as well as any application that requires a high-current source.

    Built-in Timer

    The TEST-905’s built-in timer can test the time delay characteristics of protection relays and molded-case circuit-breakers. Once the test is initiated, the current source and the timer are automatically turned on at the next zero crossing point of the AC. The timer stops when the TEST-905 input detects a change in the dry contact or voltage input, or detects the removal of the test current. The test results are then displayed in milli-seconds and fractions of a cycle(s) on the unit’s back-lit LCD screen (20 characters by 4 lines).

    External Current Input

    The TEST-905 also has an external-current input (0 – 6 A). Both the internal current source amplitude and the external current source measurement readings can be viewed at the same time.


    FEATURES


    • Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
    • Modular design to permit optimal user configuration of output current vs. unit size
    • Compact transport cart facilitates portability into switchgear rooms with limited space
    • Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result

    PARAMETERS

    Electrical parameters 
    Accuracy±0.5%
    Power Supply(AC)220V±10%·25A, 50Hz/60Hz or
    110V±10%·50A, 50Hz/60Hz
    Current Output (AC)5000A·5V or 2500A·10V
    Capacity25KVA
    The current output waveform distortion≤5%
    Dual protectionoverload electronic protection and software protection
    Primary current 
    Range0-5500A
    Resolution0.1A
    Accuracy<0.5%
    Secondary measurement 
    Range0-6A
    Resolution0.001A
    Accuracy<0.5%
    Current duration 
    5000A range5000A Continued
    2500A Continued
    2500A range2500A Continued
    With timer
    Range0.0001~999.99S
    Resolution0.001S
    Accuracy<0.5%±5 words
    Mechanical parameters 
    Dimensions (W×D×H) (mm)830×1260×2000
    Weight(kg)650
    Environmental conditions 
    Temperature-10°C to 40°C
    Relative humidity≤80%

    SELECTION GUIDE

    ModelACCU
    RACY
    Primary
    current
    AMMETER
    (0-6A)
    TIMERPOWERINJECTION CURRENT TIMEDIMENSION(W×D×H)(mm)WEIGHTREMARK
    TEST-9010.5%0-1100AYESYES5KVA1000A: 2-3min;
    500A:3-6min
    430×260×26025KGIntegrated structure
    TEST-9020.5%0-2200AYESOPTIONAL12KVA2000A:2-3min;
    1000A:3-6min
    360×300×295 and 320×300×30035KG+15KGFission structure
    TEST-9030.5%0-3300AYESOPTIONAL15KVA3000A:2-3min;
    1500A:3-6min
    380×350×360 and 340×290×42048KG+42KGFission structure
    TEST-9050.5%0-5500AYESOPTIONAL25KVA5000A:2-3min;
    2500A:3-6min
    430×430×445 and 550×450×60068KG+55KGFission structure

    Quality 5000a Three Phase Primary Injection Test Equipment For Temperature Rise Testing for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)