Sign In | Join Free | My himfr.com
Home > Electrical Power Calibrator >

Portable Voltage / Current Standard 3 Phase AC Calibrator With 63th Harmonics Output

    Buy cheap Portable Voltage / Current Standard 3 Phase AC Calibrator With 63th Harmonics Output from wholesalers
     
    Buy cheap Portable Voltage / Current Standard 3 Phase AC Calibrator With 63th Harmonics Output from wholesalers
    • Buy cheap Portable Voltage / Current Standard 3 Phase AC Calibrator With 63th Harmonics Output from wholesalers
    • Buy cheap Portable Voltage / Current Standard 3 Phase AC Calibrator With 63th Harmonics Output from wholesalers

    Portable Voltage / Current Standard 3 Phase AC Calibrator With 63th Harmonics Output

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF303
    Certification : ISO9001, CE, UL, KEMA
    Payment Terms : L/C, D/P, D/A, T/T, Western Union, MoneyGram
    Supply Ability : 200SETS
    Delivery Time : 2-3WEEKS
    • Product Details
    • Company Profile

    Portable Voltage / Current Standard 3 Phase AC Calibrator With 63th Harmonics Output

    GF303 portable 3 phase ac voltage and current standard Electrical Power Calibrator with 63th harmonics output


    GF303 portable 3 phase ac voltage and current standard Electrical Power Calibrator with 63th harmonics output is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.


    Power calibrators and power quality calibrators GF333V2 - Three-phase Fully Automatic Test System with Reference Standard and Integrated Current and Voltage Source The Calmet GF303P portable test system consists of a three-phase reference meter of accuracy class 0.04% (or 0.1%) and an integrated three-phase current and voltage source up to 3x120A/600V



    Split-phase power systems achieve their high conductor efficiency and low safety risk by splitting up the total voltage into lesser parts and powering multiple loads at those lesser voltages while drawing currents at levels typical of a full-voltage system. This technique, by the way, works just as well for DC power systems as it does for single-phase AC systems. Such systems are usually referred to as three-wire systems rather than split-phase because “phase” is a concept restricted to AC.


    GF303 is electric AC/DC power and energy calibrator for calibration of power meters, power transducers, power quality analysers and generally all kinds of power measuring devices. AC voltage, current, power and energy functions have calibrated phase shift in frequency range from 45 Hz to 65Hz with resolution as good as 0.001 Hz.


    As power grids get bigger and carry more power, the need for quick, reliable disconnection when faults occur becomes more urgent. The purpose of protective relay equipment is to sense fault states and trip circuit breakers. If a fault isn’t corrected early, personal injuries and damage can occur. Megger’s next generation of programmable secondary relay test systems are designed specifically to test microprocessor, solid state and electromechanical relays. New generation single phase and three phase test systems with remote control facilities and analytics software can make life much easier for protection test engineers.


    FEATURES

    • To set up and take the load regulation of voltage, current, phase angle, frequency and power factor, also can be used as AC current source, AC voltage source or power source.
    • To set 2-128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output.
    • Frequency value is adjustable (AB and phase C).
    • Voltage, current output a wide range, big power, high stability, waveform distortion degree is small.
    • Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%.
    • To apply the 32 bit MPU + DSP + FPGA, powerful flexible.
    • To use hardware PID, fast response, the change of load will not cause output volatility.
    • Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small.
    • Range switching automatically
    • To use software calibration, simple operation, stable and reliable.
    • To have big screen, 320 x 240 LCD display, Chinese or English interface, operating simply.
    • To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically.
    • With RS232 interface, and PC connection
    • To take place machine software, it can be output through the PC software program.

    PARAMETERS


    Electrical parameters 
    Accuracy class0.05%, 0.1%
    Power supplySingle phase AC 85V-265V, 50/60 Hz
    AC Voltage output 
    Range (U1, U2, U3 phase)57.7V/100V/220V/380V, switch automatically (max 420V)
    Adjustment resolution0.01%, 0.1%, 1%, 10%,
    Accuracy0.05% RG
    Stability0.005% RG/1min
    Distortion degreebetter than 0.1% (not capacitive load)
    Load Capacity25VA
    Full load regulation rateLess than 0.01% RG
    Full load regulation timeLess than 1mS
    Temperature drift8 PPM / °C
    Long-term stability60 PPM/year
    AC Current output 
    Range (I1, I2, I3 phase)0.1/0.25A/0.5A/1A/5A/10A/20A, switch automatically
    Adjustment resolution0.01%, 0.1%, 1%, 10%,
    Accuracy0.05% RG
    Stability0.005% RG/1min
    Distortion degreebetter than 0.1% (not capacitive load)
    Load capacity25VA
    Full load regulation rateLess than 0.01% RG
    Full load regulation timeLess than 1mS
    Temperature drift8 PPM/°C
    Long-term stability60 PPM/year
    Power output 
    Active power accuracy0.05%
    Reactive power accuracy0.1%
    Stability0.005% RG/1min
    Phase 
    Range0°-359.99°
    Adjustment resolution0.01°, 0.1°, 1°, 10°
    Accuracy0.03°
    Power factor  
    Adjusting range-1 to 0 to +1
    Resolution0.0001
    Accuracy0.0005
    Frequency 
    Range40-65Hz or 40-400Hz (option)
    Adjustment resolution0.001Hz, 0.01Hz, 0.1Hz, 1Hz
    Accuracy0.002Hz
    Temperature drift0.5PPM/°C
    Long-term stability4 PPM/year
    Harmonic 
    Harmonic times2-128
    Adjustment resolution0.1% (compared with fundamental wave)
    Harmonic content (compared with fundamental wave)
    Voltage≤40%
    Current≤40%
    Phase0°-360°
    Capacitive load capacity 
    0 - 280 V1uF
    280 - 420 V0.6uF
    Mechanical parameters 
    Dimensions (W×D×H) (mm)450x380x160
    Weight (kg)18
    Environmental conditions 
    Working temperature0°C to 40°C
    Storage conditions-30°C to 60°C
    Relative humidity≤85%

    SELECTION GUIDE

    No.AccuracyVoltage rangeCurrent rangeWeightRemark
    30306010.10%0-264V0-6A12KG 
    30306050.05%0-264V0-6A12KG 
    30312010.10%0-420V0-12A13.5KG 
    30312050.05%0-420V0-12A13.5KG 
    30320010.10%0-420V0-20A18KG 
    30320050.05%0-420V0-20A18KG 
    303H06010.10%0-300V0-6A15KGXP system
    303H06050.05%0-300V0-6A15KGXP system
    303H12010.10%0-420V0-12A18KGXP system
    303H12050.05%0-420V0-12A18KGXP system
    303H20010.10%0-420V0-20A20KGXP system
    303H20050.05%0-420V0-20A20KGXP system