Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation

    Buy cheap Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation from wholesalers
     
    Buy cheap Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation from wholesalers
    • Buy cheap Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation from wholesalers

    Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GFLZZ0973-10G2
    Certification : CE, UL, KEMA, ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 10000 PCS/MONTH
    Delivery Time : 2-3 weeks
    • Product Details
    • Company Profile

    Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation


    Resin 10KV Accuracy Class 0.5 Instrument Current Transformer Indoor


    Introduction


    Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit.
    Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
    Current transformers (CT) are a series connected type of instrument transformer. They are designed to present negligible load to the supply being measured and have an accurate current ratio and phase relationship to enable accurate secondary connected metering.
    Current transformers are often constructed by passing a single primary turn (either an insulated cable or an uninsulated bus bar) through a well-insulated toroidal core wrapped with many turns of wire. This affords easy implementation on high voltage bushings of grid transformers and other devices by installing the secondary turn core inside high-voltage bushing insulators and using the pass-through conductor as a single turn primary.



    PARAMETERS


    Technical parameters 
    StandardsIEC60044; IEC 61869; ANSI/IEEE C57.13
    Rated primary current5-1250A
    Rated load≤15VA
    Rated frequency50Hz or 60Hz
    Rated secondary current5A or 1A
    Rated short-time thermal current140kA, 1S
    Rated dynamic current350kA
    Rated insulation level12/42/75KV
    FS≤10
    Mechanical parameters 
    MaterialEpoxy resin
    Weight (kg)25
    Operating conditions 
    Operating temperature-25°C to +55°C
    Daily average temp<+40°C
    Storage temperature-40°C to +70°C
    Altitude<1000 meters
    ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.



    TECHNICAL DATA


    Ratied Primary Current(A)Class CombinationAccuracy class and Rated output(VA)Short-time thermal current
    (kA/S)
    Rated dynamic current
    (kA)
    0.510P
    5-1500.2(S)/10P
    0.5/10P
    1015150 I1n375 I1n
    2003690
    30045100
    400-60063150
    800-1000100250
    1250140350


    Overall Dimensions