    Brand Name : GFUVE
    Model Number : GF312D1
    Certification : CE, ISO9001
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 200SET/MONTH
    Delivery Time : 2-3weeks
    • Product Details
    • Company Profile

    Handheld Electrical Test Meter Calibration Durable Power Engineering Devices


    Handheld Three Phase Electric Meter Calibration and Testing of Power Engineering Devices


    The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.


    Application


    The devices used to calibrate electricity meters must be routinely verified themselves. That’s the only way to protect consumers. Laborelec’s working standards are well suited to the task. We can carry out calibration on your site, minimising disruption to your calibration routine.

    Laborary has a fully equipped calibration equipment with the most accurate energy standard. It can furnish an extensive accreditation portfolio that is recognised internationally.


    FEATURES

    1. Three phase active or reactive electricity energy meter.
    2. Calibrate three phase, single phase, and active or reactive meter error.
    3. Measure U(voltage) of three phase or single phase.
    4. Measure I(current) of three phase or single phase.
    5. Measure active power of three phase or single phase.
    6. Measure reactive power of three phase or single phase.
    7. Measure apparent power of three phase or single phase.
    8. Measure power factor of three phase or single phase.
    9. Measure phase angle between voltage and current.
    10. Measure frequency of power line.
    11. Display vector diagram.
    12. Display waveform of U and I.
    13. Analyze and display content of harmonic of U and I.
    14. Measure 2-64 harmonic of U, I.
    15. Store and display measured data.
    16. Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.
    17. Measure CT variable ratio.
    18. Measure the ratio or lag-angle of low-voltage transformer.
    19. Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD.
    20. Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity.
    21. Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.

    PARAMETERS


    Electrical parameters 
    Accuracy class0.05%, 0.1%
    Resolution6”TFT (640×480)
    Power supply220V±10%, 50/60Hz
    Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
    Power line supply (U1, UN), 85V-265V 50/60Hz
    Communication portRS232
    Test voltage 
    Range0-480V
    Error±0.05% (30V-480V)
     ±0.1% (5V-30V)
    Harmonic2nd-64st
    Test current 
    Range (direct connection)5mA-20A
    Error (direct connection)±0.05% (100mA-20A)
    ±0.1% (10mA-100mA)
    Range (clamp CT)10mA-3000A
    Error (camp CT)±0.2% (100mA-100A)
    ±0.5% (100A-3000A)
    Harmonic2nd-64st
    Power measure error 
    Active power (direct connection)±0.05% (0.1A-20A)
    ±0.1% (0.01A-0.1A)
    Reactive power (direct connection)±0.1% (0.1A-20A)
    Energy measure error 
    Active energy (direct connection)±0.05% (0.1A-20A)
    ±0.1% (0.01A-0.1A)
    Reactive energy (direct connection)±0.1% (0.1A-20A)
    Phase angle 
    Range0o-360o
    Resolution0.01o
    Error±0.05o
    Frequency 
    Range45-65Hz
    Resolution0.001Hz
    Error0.002Hz
    Pulse input 
    Input channel2
    Input level5-24V
    Input frequencyMax. 2MHz
    Pulse output 
    Energy constant180000imp/kWh, 1800imp/kWh, 180imp/kWh
    Pulse ratio1:1
    Output level5V
    Function 
    Vector diagramYes
    WaveformYes
    Energy accumulationYes
    Communication with PCYes
    Mechanical parameters 
    Instrument dimensions (W×H×D) (mm)245×162×60
    Instrument Weight (kg)1.8
    Carry case dimensions (W×H×D) (mm)450×320×185
    Carry case (kg)10.6
    Environmental conditions 
    Ambient temperature-10°C to 55°C
    Relative humidity15%-85%