    Brand Name : GFUVE
    Model Number : LZCK322-10-2
    Certification : CE, UL, ISO9001
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 50000 PCS/MONTH
    Delivery Time : 3-7 days
    • Product Details
    • Company Profile

    11KV Resin Cast Split Core Current Transformer , Low Voltage Current Transformer Outdoor


    Resin 11KV Split Core Current Transformer Outdoor High Quality


    Introduction


    LZCK series split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.
    It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.
    The transformer can be directly installed at the inlet and outlet cables. The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.



    Features


    The current transformer with high strength PVC shell, all cast bus structure. Transformer directly stuck in the cable Three rubber rings to resist the cable and cable with one. Transformer core using high-quality silicon steel roll, the second wire wound evenly on the core. Transformer open structure can not cut off the cable installation



    PARAMETERS


    Technical parameters 
    StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
    Accuracy Class0.5S, 0.5%, 1%, 3%
    Range of primary rated current100-1500A
    Range of Rated load≤10VA
    Rated frequency50/60Hz
    Rated secondary current5A or 1A
    Rated short-time thermal current40kA, 1S
    Rated continuous thermal current150%I1n
    Secondary winding power frequency withstand voltage3kV, 1min
    Safety Factor Rating(FS) <10
    Output signal1A, 5A, 333mV, 1V or 5V(customized)
    Cable length2.5m, 5m, 10m(customized)
    Flame retardant ABS plastic shell inside, jaw waterproof apron.
    Mechanical parameters 
    Aperture (mm)Φ55
    Dimensions (W×D×H) (mm)180×138×52
    Weight (kg)2
    Working conditions 
    Operating temperature-35°C to +65°C, not exceeding +40°C
    Storage temperature-40°C to +70°C
    Ingress ProtectionIP65
    Environmentoutdoors or indoors
    The Height of above sea level0- 3000m
    ConditionsNo existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

    SELECTION GUIDE


    Technical parameters 
    StandardsIEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
    Rated primary current30-600A
    Rated load≤10VA
    Rated frequency50Hz or 60Hz
    Rated secondary current5A or 1A
    Rated short-time thermal current40kA, 1S
    Rated continuous thermal current120%I1n
    Secondary winding power-frequency voltage3kV, 1min
    Instrument security factorFS≤10
    Mechanical parameters 
    Dimensions (W×D×H) (mm)φ50xφ110x52
    Weight (kg)1.6
    Operating conditions 
    Operating temperature-35°C to +55°C
    Daily average temp<+40°C
    Altitude<3500 meters
    ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

    TECHNICAL DATA


    TypeLZCK322-10LZCK322-10
    PurposeMeasuring current transformerProtection current transformer
    RatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)
    I1/I20.51310P1510P1010P5
    30/1 11.5   
    50/1 12  1.25
    75/1 1.52.5 12
    100/122.53 1.52.5
    200/12.5  1.252.5 
    300/13.75  1.252.5 
    400/17.5  1.252.5 
    500/110  1.253 
    600/110  1.53 
    50/5  2.5   
    75/5  2.5   
    100/52.5     
    200/53.75     
    300/55     
    400/57.5   2.5 
    500/57.5   2.5 
    600/510   3.75 

    SELECTION GUIDE


    ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
    LZCK-55100-1500A≤10VAφ55180×138×522PCIP65
    LMCK185-10300-3000A≤25VAφ185350×283×554.5PCIP65
    LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)
    LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)
    LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)
    LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)

    Wiring diagrams


    P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
    P2, S2 is homonymous terminals (subtractive polarity).