Sign In | Join Free | My himfr.com
Home > Electrical Test Equipment >

GF333 Electronic Testing Tools Three Phase Standard Meter High Stability

    Buy cheap GF333 Electronic Testing Tools Three Phase Standard Meter High Stability from wholesalers
     
    Buy cheap GF333 Electronic Testing Tools Three Phase Standard Meter High Stability from wholesalers
    • Buy cheap GF333 Electronic Testing Tools Three Phase Standard Meter High Stability from wholesalers
    • Buy cheap GF333 Electronic Testing Tools Three Phase Standard Meter High Stability from wholesalers

    GF333 Electronic Testing Tools Three Phase Standard Meter High Stability

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF333
    Certification : CE,ISO9001:2008,IEC
    Price : US$10000~US$12000/Set
    Payment Terms : Western Union, T/T
    Supply Ability : 10Sets/Month
    Delivery Time : 12days upon receipt of payment
    • Product Details
    • Company Profile

    GF333 Electronic Testing Tools Three Phase Standard Meter High Stability

    GF333 Multi-function three phase Standard Meter with high stability

    (Accuracy class 0.02%/0.05%)


    GF333 can be used as a calibration device standard meter, also as a testing calibrator in measurement test center of grid corporation, power company and measurement department in power plant, national levels of measurement mechanism, quality inspection departments, research institutes, tertiary institutions, industrial and mining enterprises, electric energy meter and electrical instrument production enterprises etc.


    Functions and Features

    1. Measure the AC voltage, current, active power, reactive power, frequency, phase angle and power factor etc;

    2. Measure the AC voltage, current 2~31 harmonic content and waveform distortion degree;

    3. Measure active power energy error, reactive power energy error, the maximum output pulse frequency is to 2 MHZ;

    4. Measure calibration device of voltage, current, power stability;

    5. Measure calibration device the standard deviation of estimate;

    6. Measure the voltage of the calibration device three-phase symmetric degrees, the current of three three-phase symmetric degree;

    7. Measure calibration device of the magnetic induction;

    8. Measure DC voltage and DC current;

    9. Transducer measurement;

    10. With RS232 interface, it can be controlled by PC operation;

    11. Core part uses the 32 bit DSP and16 bit low power and high speed DAC consists of high accuracy AC collector.

    12. Using 6.5 inch TFT color LCD screen, character display clear chart. Have the advantages of wide measuring range, high precision, stable and reliable operation, simple operation etc.


    Electrical parameters 
    Accuracy class0.02%, 0.05%
    Power supplyAC 220 V±10% or 110 V±10%, 50/60Hz
    Power consumption<30VA
    Warming-up time<30min
    Voltage measurement 
    U1, U2,U36.25V, 12.5V, 25V, 50V, 100V, 200V, 400V, 800V (switch automatically), max 1000V
    Range(0-120%)RG
    Resolution0.01%RG
    Accuracy0.02%RD or 0.05%RD
    Current measurement 
    I1, I2, I30.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100A(switch automatically)
    Range(0-120%)RG
    Resolution0.01%RG
    Accuracy0.02%RD or 0.05%RD
    Power measurement 
    Active accuracy0.02%RD or 0.05%RD
    Reactive accuracy0.05%RD or 0.1%RD
    Apparent accuracy0.02%RD or 0.05%RD
    Energy measurement 
    Active accuracy0.02%RD or 0.05%RD
    Reactive accuracy0.05%RD or 0.1%RD
    Phase measurement 
    Range0.00°-359.99°
    Resolution0.001°
    Accuracy0.02° (voltage ≥50V and current ≥250mA)
    Frequency measurement 
    Range45-65Hz
    Resolution0. 001Hz
    Accuracy0.002Hz
    Power Factor measurement 
    Range-1.0 ~ 0 ~ +1.0
    Resolution0.0001
    Accuracy0.0005
    Electric energy pulse output 
    Pulse constant range1-2880000000
    Output frequency of max. pulse600 kHz
    Load capacity>2mA
    Default pulse output frequency10kHz-600kHz
    Energy pulse Input 
    Input range of pulse constant600-700000
    Setting range of test pulse1-999999999
    Max. pulse receiving frequency2MHz
    Pulse input level5V
    Voltage/current harmonics measurement 
    Times2-31
    Error0.05%
    Distortion degree error0.05%
    Transducer measurement 
    DC voltage range±1, ±5, ±10, ±20 V
    Accuracy0.01%
    DC current range±1, ±2.5, ±5, ±10, ±20mA
    Accuracy0.01%
    Ripple error1%
    DC measurements (option) 
    DC voltage50V, 100V, 200V, 400V, 800V (switch automatically), max 1000V
    Range(0 -120%) RG
    Resolution0.01% RG
    Accuracy0.02% RD
    DC current0.1A, 0.3A, 1A, 3A, 10A, 30 A(switch automatically)
    Range(0-120%) RG
    Resolution0.01% RG
    Accuracy0.02% RD
    Mechanical parameters 
    Dimensions (W×H×D) (mm)440×360×160
    Weight (kg)10
    Environmental conditions 
    Operating temperature10°C to 30°C
    Relative humidity≤85%