Sign In | Join Free | My himfr.com
Home > Clamp On Current Transformer >

Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output

    Buy cheap Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output from wholesalers
     
    Buy cheap Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output from wholesalers
    • Buy cheap Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output from wholesalers
    • Buy cheap Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output from wholesalers
    • Buy cheap Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output from wholesalers
    • Buy cheap Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output from wholesalers

    Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : Q70-2
    Certification : CE UL, CNAS
    Price : Negotiable
    Payment Terms : T/T, Western Union, L/C, MoneyGram, D/P, D/A
    Supply Ability : 5000 pieces per month
    Delivery Time : Within 7 Days
    • Product Details
    • Company Profile

    Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output

    Q70 Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output Class 0.2


    The model GFUVE Split Core Current Sensor Q70-2 is suitable for 0-1000A current measurement, both cable and copper bus bar online measurement.

    When the GFUVE Split Core Current Sensor Q70-2 making a measurement, the current carrying conductor is not broken and remains electrically isolated from the measuring devices input terminals.


    Clamp-On Current Transformers are the one-handed operating solution for temporary energy audits or long-term energy studies. The GFUVE 1000A Clamp On Current Transformer is specifically designed to offer broad utility in a compact shape. These CTs deliver high-accuracy, high-sensitivity, versatility, and low phase shift.


    GFUVE Clamp-on Current Transformer are designed for fast and easy installation.Clamp-on Current Transformer uses Permalloy magnetic core or Silicon and amorphous core, with characteristics of small size, high precision, good stability and strong anti-interference ability.


    Why Choose GFUVE Current Probes. The Most Comprehensive Line of Current Probes. GFUVE ® the world's largest supplier, offers current probe models capable of accurately measuring from the low µA to kA range. A wide variety of configurations and jaw sizes are available. Probe types include iron core, Hall Effect, Flux Gate, and Rogowski etc.


    Features

    It is suitable for 1000 A, the following cable, copper bus bar online measurement.
    Holding wire diameter: 60mm×70mm
    Dimension: 122mm×275mm×35.5mm
    Load capacity: mA output ≤4Ω,
    1A output 0.1Ω, 5A output 2.5VA
    Installation: clamp type
    Output mode: lead output


    Applications

    Electric energy meter calibrator (on site)

    Double clamp type ground resistance tester

    Double clamp type phase volt-ampere meter

    Digital multi-meter

    Multi-function energy meter

    Power quality analyzer

    Matched instruments

    Calibration instrument on site


    Parameter

    Electrical parameters
    Ratio1000: 1 or 2000:1 (customized)
    Accuracy class0.2%, 0.5%, 1%
    Primary current0 - 1000A AC
    Secondary current0 - 5A AC (customized)
    Max. Cont. Input current1200A
    Over voltage categoryCAT III 600V
    Output signal (AC current)500mA,1A,5A AC at nominal input current
    Output signal (AC voltage)500mV,1V,5V AC at nominal input current
    Frequency range40Hz-2000Hz
    Dielectric strength3KV 50Hz/60Hz at 1 minute
    Temperature range-20°C to +55°C
    Output2.5 meter cable with D01 connector
    Max. voltage not insulated conductors600 V
    StandardEN 61010-1, EN 61010-2-032, IEC60044-1
    InstallationClamp type
    Output modeLead output (2.5m)
    Mechanical parameters
    Dimensions (L x W x H) (mm)122 x 275 x 35.5
    Weight (g)720
    Holding wire diameter (mm)φ60 x 70
    Max. jaw opening (mm)60
    Jaw colorWhite
    MaterialPC+ABS+Polycarbonate, UL94 V0

    FAQ, following questions will help you to select the matched probe for your applications.

    1. Please determine if you are measuring AC or DC?

    GFUVE Q70-2 is for AC metering..


    2. What is the maximum current you will measure?

    Q70-2 maximum current is 1200A


    3. What size conductor will you clamp onto? This parameter determines the probe jaw size needed.

    Q70-2 can clamp bus-bar with diameter within φ60mm x 70mm


    4. What type of probe output do you need or can you work with (mA, mV, A, AC, etc.)?

    Q70-2 can customize output with A, mA, V


    5. What is the working voltage of the conductor to be measured?

    GFUVE probes should be used below 600 volts


    6. What type of termination do you need: jacks, leads or BNC?

    Q70-2 standard has 2.5meter leads. We can offer jacks or BNC… as options.


    7. If you cannot find information you need or would like assistance, contact us today. We have designed many more probes than those shown in this catalog, and we manufacture in Beijing, China.


    Photos

    Quality Clamp Type Oscilloscope Clamp On Current Transformer 1000A / 1A Lead Output for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)