Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V

    Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers
     
    Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers
    • Buy cheap Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V from wholesalers

    Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : E6000
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V


    Handheld Three Phase Power Quality And Energy Analyzer


    E6000 handheld three phase power quality analyzer with CT offer the best ability in power quality analysis, E6000 handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.


    FEATURES


    • 3s statistical interval, continuously record 120h;
    • Support multi-brand current transformer;
    • Up to 8G data storage space;
    • Record up to 461 power energy parameters simultaneously;
    • Up to 6500 screenshots saved;
    • Support periodic recording function;
    • Up to 3.9M/s USB high-speed transfer;
    • Customized international report generation.

    Electrical parameters 
    Voltagerms, ava, pk+, pk-, rms-1/2, CF
    FrequencyFreq
    Currentrms, ava, pk+, pk-, rms-1/2, CF
    Power & energyP, S, Q, PF, DPF, W
    ComputationTHD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm
    Voltage harmonicTHD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm , KF
    Current harmonicTHD, DC, 1-50 Harm
    Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
    Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
    UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
    Event logVoltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation
    P, Q, S name 
    Measurement typesP: Calculate by every 10 cycles
    S: Calculated by the effective value of voltage and current
    Q: Calculated by the apparent power, active power
    DisplayTable charts, trend chart
    Measuring range/resolutionAccording to the range of the voltage and current
    measuring accuracy±0.5%
    Arms 
    Measurement modeCalculated by the square root value of 10 cycle
    Display modeEffective current value of each channel
    Measuring range/resolutionCurrent: according to the current clamps
    Option:5A/50A/100A/500A
    Current clamps: 1200A/3000A/6000A(Flexible Current Clamp)
    Accuracy0.1% + accuracy of the current clamps
    Frequency 
    Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
    Display modeMeasurement by 10 cycles
    Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
    Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
    Measurement accuracy±0.001Hz
    Half-wave RMS current/voltage 
    Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculation
    Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,Current: According to the current clamps
    measurement accuracy±0.1%
    Vrms 
    Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
    Basic frequency of the measuring circuit50Hz
    Input channels4 phase voltage, 4 phase current
    Measurement rangeVoltage measurement range: standard: 120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
    Current measurement range: according to the current clamps, only support the v signal output current clamp
    Power factor 
    Measurement modeThe ratio of average power to apparent power
    Display modeReal-time data showed
    Measurement range/resolution-1.000-1.000/0.001
    Measurement accuracy±1%
    Vfund, Afund, Harmonic power 
    Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
    Window points5120 points
    Display modeForm figure, trend charts, histograms
    Number of measurement1-50 Times
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    InHarm Voltage, InHarm current 
    Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
    Window points5120 points
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-16 groups
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    HiHarm Voltage, HiHarm current 
    Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
    Window points5120 points every 10 cycles
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-35 groups
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% rated voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% current range
    Voltage SubHarm Current SubHarm 
    Measurement modeMeet IEC61000-4-7, analysis time window is ten cycles
    Window points5120 points every 10 cycles
    Display modeForm figure, trend charts, histograms
    Numbers of measurement1-50 groups
    Measurement accuracyVfund >1%: Error<1%
    Vfund <1%: Error<0.05% Rated Voltage
    Afund >3%: Error<1%
    Afund <3%: Error<0.05% Current range
    Voltage/current Unbal (pos, neg) 
    Measurement mode3P3W or 3P4W, using three phase of fundamental wave components to calculate
    Display modeForm figure, trend charts, histograms
    Measurement accuracyVoltage unbal: ±0.2%
    Current unbal: ±0.5%
    Voltage fluctuation 
    Measurement modeCalculate by the quadratic mean of half wave.
    Display modeForm figure, trend charts
    Measurement accuracy±1%
    IEC Flickering 
    MeasurementP short term (Pst) , P long term (Plt)
    Measurement modeAccording to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt (2 hours)
    Display modeForm figure, trend charts
    Measurement range0-20
    Measurement accuracy±5%
    Surge current 
    Measurement modeHalf-wave RMS of current is higher than set value and sustain time is 10ms-1min
    Display modeMaximum of the surge current and surge current wave
    Measurement accuracy0.10%
    Voltage swell, Voltage sags, DIP 
    Measurement modeSwell: When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.
    Sags: When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.
    DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
    Display modeSwell, sags, DIP wave sustain time, extent and so on.
    Measurement accuracy0.10%
    Machinery 
    Size263mm x 168mm x 65mm
    Weight2KG
    Power supply 
    Voltage input110V-240V
    Adapter output15V, 3A
    BatteryRechargeable nickel metal hydride, 4500mAh
    Battery working time4h
    Battery recharging time5h (Environment temperature 25°C)
    Power saving facilityLCD backlight brightness is adjustable, standby time is adjustable
    Display 
    Size112.8 x 84.6mm
    Color260000 color
    Resolutions640 x 480
    BrightnessMax 350 cd/m2 (Typ), brightness is adjustable
    Contrast500:1 (Typ)
    Visual angle70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
    Store 
    TypeTF card (inbuilt)
    Size8G
    Standards 
    Measurement methodIEC 61000-4-30
    Measurement performanceIEC 61000-4-30 A LVL
    FlickeringIEC 61000-4-15
    HarmonicIEC 61000-4-7
    Safety 
    StandardGB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and laboratory electrical equipment safety requirements", first part: general requirements.
    Security level: CAT III 1000 V/ CAT IV 600 V.
    MAX voltage of phase angle inputCAT III 1000V/CAT IV 600V
    Environmental conditions 
    Working environment0°C to +45°C, humidity below 90rh%
    Storing environment-20°C to +50°C, humidity below 95rh% (non-condensing)

    Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V

    Quality Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)